Abatement system selection and the final design are
based on emission constiuents, concentrations and
airflow. Rarely will these process conditions remain
unchanged for the life of an oxidizer, possibly resulting
in shutdowns, a decrease of DRE (Destruction Removal
Efficiency) and increase in energy consumption.
Even when manufacturing processes remain consitent, the
time will come when certain components should be replaced or
upgraded. Take for example an older RTO (Regenerative
Thermal Oxidizer) originally designed for nominal 95% TER (Thermal
Energy Recovery). Five years after installation,
advances in the ceramic media now allow for 97%.
This might not sound like a big deal, however an average sized
RTO (25,000 SCFM) operating for a full year at 95% TER versus
today's standard of 97% is using 40% more natural
gas.
The Anguil Site Services
team regularily provides the following retrofits and upgrades on a
wide variety of makes and models, on average we
service oxidizers made by eighteen different manufacturers every
year.
- Increasing Flow Capacity
- Improving VOC Capture
- Increased Destruction
- Down Time Reduction Plans
- Technology Conversions
- Energy Efficiency Upgrades
- Operating Cost Reviews
- System Relocation
These energy saving strategies not only cut operating costs but
also reduce GHG (Green House Gas) emissions. With carbon
legislation looming, implementing these oxidizer
enhancements could provide additional savings through credits
and improve a facility's image as a good enviromental steward.
Other Aftermarket Services Include: Preventive Maintenance
Evaluations, General Services and Spare Parts